Laserfiche WebLink
and safety, aesthetics, maintainability, capacity of existing infrastructure, and sustainability <br />are important characteristics of a site's stormwater management plan. <br />Stormwater Management Facility: Any structure or configuration of the ground that is <br />used as, or by its location becomes, a place where stormwater flows or is accumulated, <br />including but not limited to, pipes, manholes, catch basins, ponds, open drainage ways, <br />runoff control facilities, wetlands, and their accessories. <br />Stormwater Quality Facility: Any structure or drainage device that is designed, <br />constructed, and maintained to collect and filter, retain, or detain surface water runoff <br />during and after a storm event for the purpose of maintaining or improving surface and /or <br />groundwater quality. <br />Surface Conveyance: The transport of stormwater on the ground surface from one point to <br />another. <br />Surface Infiltration Facility: A facility designed to receive and infiltrate stormwater runoff <br />at the ground surface to meet stormwater flood control requirements. <br />Surface Retention Facility: A facility designed to receive and hold stormwater runoff at the <br />ground surface. Rather than storing and releasing the entire runoff volume, surface <br />retention facilities permanently retain a portion of the water on -site, where it infiltrates, <br />evaporates, or is absorbed by surrounding vegetation. <br />Tenant Improvements. Upgrades made to the interior or exterior of buildings to meet the <br />needs of the tenant. Tenant improvements may trigger Chapter 3.0 Source Controls if they <br />take place on sites with specified high -risk activities. <br />Time of Concentration (T c ): The amount of time it takes stormwater runoff to travel from <br />the most distant point (measured by travel time) on a particular site or drainage basin to a <br />particular point of interest, such as to an on -site retention system. <br />Total Suspended Solids (TSS): Matter suspended in stormwater excluding litter, debris, <br />and other gross solids exceeding 1 millimeter in diameter. <br />Underground Injection Control (UIC): A federal program under the Safe Drinking Water <br />Act, delegated to the Oregon Department of Environmental Quality (DEQ), which regulates <br />the injection of water below ground. The intent of the program is to protect groundwater <br />aquifers, primarily those used as a source of drinking water, from contamination. <br />Vegetated Facilities: As used in this manual, stormwater management facilities that rely on <br />plantings to enhance their performance. Plantings can enhance many facility functions, <br />including infiltration, pollutant removal, water cooling, flow calming, and prevention of <br />erosion. <br />Volume -Based Facility. A stormwater quality facility, such as a wet pond, which is sized to <br />store and treat a particular volume of runoff. <br />Stormwater Management Manual 1 11 <br />Eugene 2014 <br />