Laserfiche WebLink
· .211 CELL 'lOWERS ~ TOWERS 212 <br /> <br /> recent U.S.G.S .Quadrangle map, at a scale of and Longitude. <br /> 1.'.25,000, .and .showing the area within at least two m. Mounting locations on Tower or structur~ <br /> · <br /> · miles fi-om the proposed Facility Site. Indicate the including height above ground. <br /> location of the proposed Personal Wireless Service iv. ' Anteama type(s), manufacturer(s), model <br /> FacilitY, .or of.the Facility undergoing Major number(s). <br /> Modification, and the exact Latitude and Longitude v. For each Antenna, the Antenna gain and <br /> (degrees, minutes and seconds).' Antenna radiation pattern. <br /> b. Proposed Facility Plan: A recent survey of the vi. Number of channels per Anteama, projected <br /> Facility Site at a scale, no smaller than 1" = 40' and maximum <br /> (1:480 or metric equivalent 1:500) showing: vii. Power input to the Antenna(s). <br /> i. Horizontal and radial, distances of Antenna(s) to viii. Power output, in normal us~ and at maximum <br /> nearest point on property line. - output for each Antenna and all Antennas as <br /> ii. Horizontal and radial distances of Antenna(s) an aggregate. <br /> to nearest dwelling unit. ix. Output frequency of the Transmitter(s). <br /> iii: Proposed utilities, including distance from <br /> Souroeofpower, sizes of service available and This inforn~tjon is critical as it gives your <br /> required,, locations of any propo~xl utility or independent consultant the irfformation needed lo <br /> communication lines, and whether assess the coverage and to generate a Radial Plot <br /> underground or above ground, to determine whether the information being <br /> iv. Any changes to be made to the e0dsting provided by the currier is accurate aod cotnple~. <br /> Facility's landscaping, screening, fencing, Do not be tempted to jettison the engineering detail <br /> lighting, drainage, wetlands, grading, just becamse it is technical,..or because you do not <br /> . driveWays or roadways, parking, or other understand the meaning of the term~ It is not <br /> infi-as~ct~e as a result of. this proposed necesmw),for laypeople to under~mw.h detail. If <br /> MOdification of the Facility. this detail is not required in tl~ applic~on, the <br /> .-c. .Proposed Communiemtions Equipment Shelter: it~__;.stry does not have to provide it. Your engin~r <br /> i. Floor Plans, elevations and ero~S sections at a will then.be working with incomplete informatior~ <br /> scale of no smaller that 1/4" = 1' (1:48) of any <br /> proposed appurtenant structure. · VIII § 171 - 127. General Requirementm <br /> ii. Repro~entatj.'ve elevation vieW~, indicating the A. New Towers shall be set back at least one (1) time tho height of <br /> · root~ facades, doors and other e~terior the Tower, plus $0', from all boundaries of the'Site on which <br /> appearance and materials, the Tower is located. <br /> .d. Propo.~d Equipment Plan: . B. ff the Facility or Tower Site is in a wooded area, a vegetated <br /> i. plans, . elevations, sections and details at buffer strip of undisturbed tree~ shall bo retained'for atleazt 50 <br /> appropriate scales but no smaller than 1" = feet in width around the entire perimv~.,r ~raT~pt where the <br /> 10'. - ace, s drive is located. Applicarm fl~l obtain a finamial ~ur~ty <br /> ii. Number of Antennas and Repeaters, as well as to cover tho cost of tho rom0diation of any damage to'the <br /> .... tim exact locations, of Antenna(s) and of all landscapowhichoeeur~ duringthe ¢lmringofthe Site. <br />,. Repe, aters (if any) located on a map as well as C. Fearing and Signs: Tho ~ around tho Toji~r and <br /> ~- by degree, minute, z, and second~ of Latitude .... i Co~municaRion F, quipmeaR Shdt~s) ~ bo ¢ ~letoly <br /> <br /> <br />