Laserfiche WebLink
9.2470Employment andIndustrial Zone Lot Standards. <br />The following Table 9.2470 <br />sets forth lot standards within employment andindustrial zones. The numbers <br />enclosed within (#) indicate a special standard of EC 9.2471. <br />Table 9.2470 Employment and Industrial Zone Lot Standards <br />E-1E-2I-2I-3 <br />Area Minimum <br />(1) <br />All Lots 2 acres6,000 square 6,000 square 6,000 square <br />feetfeetfeet <br />Frontage Minimum(1) <br />Interior Lot50 feet50 feet50 feet50 feet <br />Corner Lot50 feet50 feet50 feet50 feet <br />Curved Lot35 feet35 feet35 feet35feet <br />Cul-de-sac Bulb35 feet35 feet35 feet35 feet <br />Alley Access nananana <br />Flag Lot <br />1 Lot15 feet15 feet15 feet15 feet <br />2 to 4 Lots25 feet25 feet25 feet25 feet <br />WidthMinimum (1) <br />Interior Lot50 feet50 feet50 feet50 feet <br />Corner Lot50 feet50 feet50 feet50 feet <br />Curved Lot35 feet35 feet35 feet35 feet <br />Cul-de-sac Bulb35 feet35 feet35 feet35 feet <br />Alley Access 50 feet50 feet50 feet50 feet <br />Flag Lot40 feet20 feet20 feet20 feet <br />Section 29. <br />Subsection (20)(f)of Section 9.2530 of the Eugene Code, 1971, is amended <br />to provide as follows: <br />9.2530Natural Resource Zone Development Standards. <br />In addition to applicable <br />provisions contained elsewhere in this code, the development standards listed in <br />this section shall apply to development in the NR zone, as specifically provided in <br />EC 9.2520 Natural Resource Zone Land Use and Permit Requirements. In cases of <br />conflict, the standards specifically applicable in the NR zone shall apply. <br />(20)Noise. <br />For inventoried sites that received a Wildlife Habitat Rating of greater <br />than 60 in the Metropolitan Natural Resources Inventory (Lev, 1990) and sites <br />designated as high value wetlands in the wetland buffer provisions of this <br />code, noise generated by uses within the NR zone and the wetland buffer <br />overlay zone (as measured at the wetland boundary) and within the waterside <br />protection overlay zone (as measured at the top of the high bank) shall not <br />exceed the following standards: <br />(f)Exceptions. Upon written application from the owner or operator of an <br />employment andindustrialor commercial noise source, the city <br />manager or the manager's designee may authorize or conditionally <br />authorize exceptions to local noise emission standards in the following <br />situations: <br />1.Infrequent noise. <br />2.Noise levels at or anywhere beyond the property lines of the <br />property of origin when exceeded by an exempt noise, as listed in <br />Ordinance -Page 27of 48 <br />