Laserfiche WebLink
ILLUMINATION NOTES <br />OFURNISH AND INSTALL SIZE (S) RIGID ELECTRICAL CONDUIT. <br />PR FURNISH AND INSTALL SIZE (S) RIGID ELECTRICAL CONDUIT FROM JUNCTION BOX <br />S' UP POLE. FIRST 10 FT. UP POLE TO BE STEEL. CONFORM TO EWER STANDARDS. <br />EWEB FURNISH AND INSTALL SIZE (S) RIGID ELECTRICAL CONDUIT FROM JUNCTION BOX <br />S INTO EWEB SECONDARY BOX. CONFORM TO EWEB STANDARDS. <br />BPL FURNISH AND INSTALL BIKE PATH LIGHTING WITH (X) FT. LUMINAIRE <br />X -W HEIGHT AND (W) WATT HIPS BULB <br />PSL FURNISH AND INSTALL PEDESTRIAN SCALE LIGHTING WITH (X) FT. <br />X -W LUMINAIRE HEIGHT AND (Nn WATT HIPS BULB <br />HPS FURNISH AND INSTALL (W) WATT, (X) VOLT HIGH PRESSURE SODIUM <br />W_V I.E.S. TYPE M -C III CUTOFF "COBRA HEAD- LUMINAIRE, PEC NOT <br />REQUIRED. FIXTURE TO MATCH COLOR OF POLE AND LUMINAIRE ARM. <br />PS -PEC FURNISH AND INSTALL (W) WATT, (X) VOLT HIGH PRESSURE SODIUM <br />W -V I.E.S. TYPE M -C III CUTOFF 'COBRA HEAD" LUMINAIRE, PEC REQUIRED. <br />FIXTURE TO MATCH COLOR OF POLE AND LUMINAIRE ARM. _ <br />FGP FURNISH AND INSTALL GRAY FIBERGLASS LIGHT POLE TO PROVIDE <br />X A X FT. LUMINAIRE MOUNTING HEIGHT AND AN 8 FT. LUMINAIRE <br />PS -BPL FURNISH AND INSTALL (W) WATT, (V) VOLT HIGH PRESSURE SODIUM I.E.S. TYPE M -C III <br />W -V CUTOFF "STRUCTURAL STS MODEL' LUMINAIRE WITH STANDARD SUPPORT ARM AND <br />GUSSET, PEC NOT REQUIRED. FIXTURE TO MATCH COLOR OF POLE AND SUPPORT ARM. <br />FGL-BPL FURNISH AND INSTALL GRAY/BLACK FIBERGLASS LIGHT <br />X POLE TO PROVIDE A X FT. LUMINAIRE MOUNTING HEIGHT <br />S -BPL FURNISH AND INSTALL GRAY/BLACK GALVANIZED STEEL LIGHT <br />X _ POLE TO PROVIDE A X FT. LUMINAIRE MOUNTING HEIGHT <br />JB INSTALL TYPE 1 JUNCTION BOX (MARKED "LIGHTING-) <br />1 WITH CONCRETE APRON <br />JB INSTALL TYPE 2 JUNCTION BOX (MARKED "LIGHTING-) <br />2 WITH CONCRETE APRON <br />PEC FURNISH AND INSTALL PHOTOELECTRIC CONTROL IN <br />SERVICE CABINET FOR CIRCUIT CONTROL. <br />FURNISH AND INSTALL A (V) VOLT BASE MOUNTED SERVICE AND CONTROL <br />SC CABINET WITH A 16' RISER AND AN XX AMP 2 POLE CIRCUIT BREAKER (MAIN), <br />V TWO 2 POLE XX AMP CIRCUIT BREAKERS (LIGHTS), ONE XX AMP SINGLE POLE <br />CIRCUIT BREAKER (CONTROL), AND ONE 4 POLE, XX AMP PER POLE, CONTACTOR. <br />OF FURNISH AND INSTALL 2 CONDUCTOR (G) TYPE OF CABLE. <br />G <br />G FURNISH AND INSTALL(X) NO. (G) TYPE XHHW WIRES. <br />EWEB# EWEB POLE # OR VAULT # USED FOR SERVICE. <br />EX MAINTAIN AND PROTECT EXISTING SERVICE CABINET <br />SC <br />EC SIGNAL CONDUIT AND WIRING, SEE SIGNAL PLAN <br />EC MAINTAIN AND PROTECT EXISTING SIGNAL CONDUIT <br />DC MAINTAIN AND PROTECT EXISTING DETECTOR CONDUIT <br />IC MAINTAIN AND PROTECT EXISTING INTERCONNECT CONDUIT <br />EX MAINTAIN AND PROTECT EXISTING JUNCTION BOX <br />JB <br />EX MAINTAIN AND PROTECT EXISTING SIZE (S) SIGNAL CONDUIT <br />S" <br />CED <br />C DETECTOR LOOP CONDUIT AND WIRING, SEE DETECTOR LOOP PLAN <br />EX MAINTAIN AND PROTECT EXISTING WIRE. <br />W <br />FF FURNISH AND INSTALL CHANNELS (CH) FIRE PREEMPTION FEEDER <br />CH CABLE.(OPTICOM MODEL 138 SHIELDED DETECTOR CABLE) SEE <br />STANDARD DRAWING TM422 <br />SPLICE SPLICE XHHW WIRES TO OF CABLE IN JUNCTION BOX. USE APPROVED <br />COMPRESSION CONNECTORS AND HEAT SHRINK TUBING <br />H (W) WATT HPS FIXTURE ON (H) FT. POLE <br />LOCATIONS OF POLES, CONDUITS AND JUNCTION BOXES <br />AS SHOWN ON THE PLANS ARE APPROXIMATE. ACTUAL <br />LOCATIONS SHALL BE AS DETERMINED IN THE FIELD BY <br />THE ENGINEER. <br />T = TYPE SHOWN S = SIZE SHOWN G =AGW SIZE SHOWN <br />STANDARD DETAIL <br />PUBLIC IMPROVEMENT <br />DESIGN STANDARDS MANUAL <br />TYPICAL CONSTRUCTION BUBBLE NOTES <br />TRAFFIC SIGNAL NOTES <br />JUL <br />SHEET <br />11 of 11 <br />N.T.S.' <br />