My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
Admin Order 58-16-01
COE
>
City of Eugene
>
Administrative Orders
>
2016
>
Admin Order 58-16-01
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/4/2016 3:04:50 PM
Creation date
3/4/2016 10:51:32 AM
Metadata
Fields
Template:
City Recorder
CMO_Document_Type
Admin Orders
Document_Date
3/2/2016
CMO_Effective_Date
3/2/2016
Author
CRO
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
457
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
same sheet. If lengths are greater than one standard sheet width, complete curve <br />information shall be shown on all pertinent sheets. <br />C. Stationing <br />Stationing may be either from left to right or from right to left. Profile stationing shall be <br />consistent in direction to that in the plan. <br />Important stations, such as, but not limited to, beginning of curb return, PC, and PT, shall <br />be included on the plan. <br />Stationing used for streets shall be as previously established by the City (or County) for <br />the project location. <br />Stationing or lot line offsets shall be shown for all wastewater service connections and for <br />those storm connections not defined by a manhole or curb inlet. <br />D. Topography <br />All pertinent topography shall be shown on the drawing. Station and offset numbers to <br />existing individual features are not required and should only be used when there may be <br />a potential conflict with the construction activity. Utility poles and tree species and their <br />diameters shall be included. <br />E. Structure Referencing and Numbering <br />New structures in a right-of-way, such as manholes, shall be referenced by station and <br />offset from the street centerline. Any controlling factor (i.e., dimension from a building or <br />property line) affecting such a location shall also be shown. All horizontal ties shall be to <br />the center of a structure, except that measurements for curb inlets and catch basins shall <br />be referenced to the curb face. Catch basins/curb inlets outside of the plan view <br />"window" shall be noted or referred to by station and offset if they are important to the <br />project. <br />Structure numbers shall be shown on both plan and profile for all structures, which <br />include, but is not limited to manholes (new and existing), curb inlets, pipe inlets and <br />outlets. <br />F. Horizontal Curves <br />Horizontal curve data shall be shown in a table that contains the delta angle, radius, semi- <br />tangent,'length and PC and PT stations. Tables shall be referenced to curves using letters <br />inside squares. <br />G. Existing Wastewater and Stormwater Services <br />Public Improvement Design Standards Manual, 2016 Page 3-4 <br />
The URL can be used to link to this page
Your browser does not support the video tag.