Ordinance No. 18446
COE
>
City of Eugene
>
Ordinances
>
1970s No. 15850-18549 partial
>
Ordinance No. 18446
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
6/10/2010 3:41:00 PM
Creation date
5/12/2009 1:47:58 PM
Metadata
Fields
Template:
Council Ordinances
CMO_Document_Number
18446
Document_Title
An ordinance concerning the Plumbing Code; amending, repealing and adding Sections to the Eugene Code, 1971; and declaring an emergency. (See ordinance for complete list of effected sections)
Adopted_Date
8/1/1979
Approved Date
8/1/1979
CMO_Effective_Date
8/1/1979
Signer
R. A. "Gus" Keller
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
10
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
S~i~b <br />lines less than eight inches L8~' } in diameter shall be <br />one gallon per hour per ,inch of pipe diameter per one <br />hundred x.10 0 }. lineal feet of pipe . Maximum .allowable <br />leakage far pipe lines eight inches ~8"} to eighteen <br />inches ~~.18" } in diameter shah. be eight ~ 8 } gallons per <br />hour per one hundred X100} lineal, feet of pipe. A tee <br />shall be provided in the sewer for insertion of the plug <br />to be capped tightly and secured against back pressure <br />upon completion of the test. The administrative auth- <br />ority may require the ~.ine to be retested after backf fil- <br />ling has been co~pleted. ~n air test may be made in <br />lieu of the standard hydrostatic test in conformance to <br />Section 318-2 ~~,}. of this code and in conformance to the <br />procedure recommended by the administrative authority. <br />~_5} Section 4~5, Chan es in Direction of Drainage Flow, <br />Subsection ~b}., the last two sentences are deleted. <br />~6} Section 608, A l.iances, is amended to read: <br />Section- 6~_0 8,_ ~.p~;l~i~arices . Appliances , devices , equipment <br />or other apparatus not regularly classed as plumbing fixtures, <br />which are equipped with pumps, drips ar drainage outlets, maybe <br />drained by indirect waste pipes discharging into an approved type <br />open receptor. <br />When the condensate waste from air conditioning coils dis- <br />charges by direct connection, to a lavatory tailpiece or to an <br />approved accessible inlet on a bathtub overflow, the connection <br />shall be located in the area controlled by the same person con- <br />trolling the air conditioned space. <br />No domestic dishwashing machine shall. be directly connected <br />to a drainage system or food waste disposer without the use of an <br />approved dishwasher air~gap fitting on the discharge side of the <br />dishwashing machine. <br />~7}.~ Section 904, Strainers and Connections, Subsection <br />b , is amende to rea . <br />fib} Connections. Fixtures having concealed slip.- <br />joint connections shall be provided with an~access panel <br />or utility space at least twelve X12} inches ~.3m} in its <br />least dimension and sv arranged without obstructions as <br />to make such connections readily accessible for inspec- <br />tion and repair. <br />~_8} Section 1101 - Sewer Re ui.red, subsection ~d}. is <br />amended as follows <br />Substitute the words "one hundred and sixty ~1G0} <br />f eet'~ for the words "two hundred ~2 0 0 } feet"' where they <br />appear in subsection ~_d} . <br />~9 } Section ~110~5 - Size of ~u~lda,n Sewers. <br />The minimum sizE of any building sewer shall be determined on <br />the basis of .the total number of fixture units drained by such <br />sewer, in accordance with Table ~-~3 but shall be~no~less than <br />four inches ~4"} in diameter. <br />~.~,0 }~ Section 1106 - Grade, Su ort and Protection of <br />Buildin~__Sewers, is amende as ,follows: <br />_.~.~, <br />Subsection ~b~. is mended by adding the following: <br />pipe bedd~;ng material sha~,l be three-quarter inch <br />X3/4"} minus crushed rock placed in the trench base to <br />prdinance - 8 <br />