My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
Item 8 - Action MWMC SDC
COE
>
City of Eugene
>
Council Agendas 2004
>
CCAgenda-06/28/04Mtg
>
Item 8 - Action MWMC SDC
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
6/9/2010 12:55:49 PM
Creation date
6/24/2004 8:58:20 AM
Metadata
Fields
Template:
City Council
City_Council_Document_Type
Agenda Item Summary
CMO_Meeting_Date
6/28/2004
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
101
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
SYSTEM DEVELOPMENT CHARGE METHODOLOGY <br /> <br />Biosolids facilities at the WPCF and the BMF are both sized and function to treat the BOD <br />and TSS removed during the treatment process; therefore, their allocation is split equally <br />between BOD and TSS. <br /> <br />· BOD-1/2 <br />· TSS-1/2 <br /> <br />Tertiary Filters <br />The existing WPCF does not have tertiary filters. The 20-year project list recommends that <br />tertiary filters be installed to enable the WPCF to consistently meet the NPDES permit <br />discharge requirements. The permit includes mass limits for BOD and TSS. As influent <br />flows to the WPCF increase in the future, the effluent concentration required to meet the <br />mass limits decreases. Addition of the filters will assist with meeting these more stringent <br />effluent concentrations. From a functional basis, the main purpose of the filters is to remove <br />TSS, and to a lesser degree BOD. From a design criteria sizing basis, average flow is used to <br />determine the size of the facilities. In the wet weather season, a portion of the peak flow <br />may be routed to the filters for additional treatment. However, the associated peak flow <br />loading rate onto the filters will not be the limiting factor in terms of design criteria sizing. <br />Following is the allocation for the tertiary filter treatment category: <br /> <br />· Average Flow- 1/4 <br />· BOD- 1/4 <br />· TSS- 1/2 <br /> <br /> Reuse Facilities <br /> Reuse facilities may be constructed to comply with more stringent regulatory requirements <br /> related to temperature and/or thermal load restrictions of Willamette River discharges. <br /> Reuse facilities would allow flow to be diverted from the river by reusing plant effluent for <br /> irrigation. The basic design criterion used to size reuse facilities is average flow; so this <br /> parameter receives 100 percent of the allocation. <br /> <br /> · Average Flow - 100 percent <br /> <br /> Odor Control <br /> Odor control facilities function by collecting odorous air from preliminary/primary liquids <br /> treatment processes and biosolids treatment/handling processes and treating the air to <br /> remove the odors. Odor generation is dependent on the influent loading levels and, <br /> therefore, the allocation is split equally between BOD and TSS because both parameters <br /> contribute to the sizing and function of the odor control systems. <br /> <br /> · BOD- 1/2 <br /> · TSS- 1/2 <br /> <br /> Peak Flow Management <br /> There are a number of future capital improvement projects that specifically function to <br /> convey, treat, and discharge the wet season peak flow. For example, the parallel <br /> primary/secondary peak flow management approach is proposed solely to address peak <br /> <br /> SEA31003271388{DG).DOC/041040034 <br /> <br /> <br />
The URL can be used to link to this page
Your browser does not support the video tag.