5 BASIS OF PLANNING <br /> <br />5.1,6 Plant Reliability and Redundancy Criteria <br />New or .expanding treatment works are required to meet min~um standards for <br />mechanical, electrical, fluid systems, and component reliability in accordance with EPA's <br />policy. This is to ensure that the treatment facilities will operate effectively on a day-to-day <br />basis and that capabilities are provided for satisfactory operation during power fmlures, <br />flooding, peak load's, equipment failures, and maintenance shutdowns. These reliability and <br />redundancy standards are important to ensure that unacceptable degradation of the <br />receiving water will not occur as a result of the interrupted operation of specific treatment <br />operations or processes. In that regard, standards have been established for three classes of <br />wastewater treatment works. The Reliability Class I definition is applicable for the WPCF. <br />Thi~ reliability designation is based on the possible beneficial uses that may be negatively <br />affected by a WPCF failure. The Reliability Class I definition consists of the following: <br />"Works which discharge into navigable waters that could be permanently or unacceptably <br />damaged by effluent which was degraded in quality for only a few hours. Examples of <br />Reliability Class I works might be those discharging near drinking water reservoirs, into <br />shellfish waters, or ~n close proxhnity to areas used for water contact sports." <br /> <br />Table 5.1.6-t lists the mJnLmum backup requirements for plant components that may be <br />provided at the WPCF facility in accordance with EPA's Works Design Criteria, Reliability <br />Class I, for sewage treatment plants. In addition to the standards listed in the table, with the <br />exception of prLmary clarification, unit operations will be designed to pass the peak <br />hydraulic flow with one unit out of service. Also, mechanical components in the facility will <br />be designed to enable repair or replacement without violating the effluent limitati~ or <br /> control diversion. <br />causing <br /> <br />3'ABLE 5.1.6-1 <br />Reliability C~ass I Requirements <br />MWMC Facility Plan, Eugene-Springfield <br /> <br /> Plant <br /> Component Requirement <br />Raw Sewage Pumps Peak flow with largest unit out of service. Peak flow is defined as the maximum <br /> wastewater flow expected during the design pedod of the treatment works. <br />Mechanical Bar One backup with either manual or mechanical cleaning (manual cleaning r~ only two <br />Screens screens). <br />Gnt Removal Minimum of two units. <br />Primary Sedimentation 50% of design flow capaci'~ with largest unit out of sep,~ice. Design flow is defined as <br /> the flow used as the design basis of the component. <br />Activated Sludge A minimum of two equal volume basins; no backup basin required. <br />Process <br /> <br />Aeration Blowers Supply the design air capacity with the largest umt out of service; provide a minimum <br /> of two umts. <br /> <br />Air Diffusers Isolation of largest section of d~ffusers (w~thin a basin) without measurably impairing <br /> oxygen transfer. <br />Secondary 75% of design flow capacity wIth largest unit out of service. Design flow is defined as <br />Sedimentation the flow used as the design basis of the component. <br />Disinfectant Contact 50% of the design flow with largest unit out of sen/ice. Design flow is defined as the <br />Basin flow used as the design basis of the component. <br /> <br />MWMC_5 0_REVS_V~(S.DOC <br /> <br /> <br />