My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
Resolution No. 4793
COE
>
City of Eugene
>
Resolutions
>
2004 No. 4782-4819
>
Resolution No. 4793
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
6/10/2010 4:49:14 PM
Creation date
7/7/2004 4:37:39 PM
Metadata
Fields
Template:
City Recorder
CMO_Document_Type
Resolutions
Document_Date
6/28/2004
Document_Number
4793
CMO_Effective_Date
6/28/2004
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
322
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
MWMC FACJUTiES PLAN <br /> <br />Design criteria used for sizing and siting the facihty include the following: <br /> <br /> Average filter flow = 2.5 gpm/sf <br />- Peak filter fl~w = 5 gpm/sf <br /> 75% TS$ removal <br /> Total filtered flow = 30 mgd <br /> Total filter area = 7200 sf <br />,, 8 modular filter ceils each at 26 ftx 35 ff. <br /> <br />For granular media filtration a large supply of chlorinated water is needed to provide <br />backwash flows to the filters. It was assumed that a new filter backwash pump station <br />would be constructed in the existing chlorine contact basins utilizing vertical barbine pumps <br />for this purpose. It was also assumed that in the initial stages one ceil of the existing aeration <br />basins could be used for backwash equalization flow, as this volmme is currently unused. <br /> <br />Other filtration technologies listed above are well suited for smaller filtration projects and <br />should be considered to provide filtration for level IV reuse water. <br /> <br />6.3 Disinfection Alternatives <br />The WPCF currently uses a liquid/gaseous chlorine disinfection system with sulbar dioxide <br />for dechlorination. The primary use of chlorine at the WPCF is effluent disinfection. The <br />current disinfect-ion design capacity is approximately 60 mgd at 60 minutes hydrauhc <br />detention time and 175 mgd at peak wet weather flows hmited by chlorinator capacity. Flow <br />in excess of 200 mgd during peak wet weather flows have been adequately disinfected in <br />the facihty only because of the reduced chlorine dosage as a result of the diluted wastewater <br />flows. Chlorine is also used to control filamentous bulking organisms through addition to <br />the return activated sludge (R_AS) line. Table 3.2.2-4 outlines the existing WPCF disinfection <br />unit process and equipment. <br /> <br /> Up to the secondary treatment capacity of 103 - 111 mgd, all of the PE is routed through the <br /> secondary system and disinfection facilities. During PWWFs, PE in excess of 111 mgd is <br /> diverted around the secondary treatment facilities and blended with the SE upstream of the <br /> disinfection facility. This is accomphshed through a dedicated diversion channel. <br /> <br /> Projected peak in~stantaneous flows to the facility are estimated at 277 mgd. The modified <br /> secondary treatment system will handle a peak flow of 165 mgd. Therefore, flows to the <br /> facility in excess of the secondary treatment system capacity will be diverted around <br /> secondary treatment and will need to be either disinfected separately or combined with the <br /> SE prior to disinfection. Because the effluent pipe from the current disinfection system is <br /> limited in its capacity to 165 mgd (once the secondary system is modified), it will be <br /> necessary to keep the diverted PE and SE flow separate for disirffection. <br /> <br /> Due to growing concerns about operator and public safety, M%TMC initiated an <br /> investigation to evaluate disinfection alternatives other than the use of chlorine and sulfur <br /> dioxide gas. Alternatives would be required to disinfect a projected peak flow of 277 mgd. <br /> The criteria for which chlorine alternatives were evaluated were taken from the guidelines <br /> published in the Washington Department of Ecology Orange Book, which are summarized <br /> <br /> MWM~6~REVI~DOC <br /> <br /> <br />
The URL can be used to link to this page
Your browser does not support the video tag.