Laserfiche WebLink
9.3150(3), EC 9.3180(3), EC 9.3181(3), and EC 9.3182(3) shall <br />demonstrate compliance with “urban design” plan policies in <br />alternatives <br />the Downtown Riverfront Specific Area Plan; <br />proposed pursuant to EC 9.3160(7) and EC 9.3165(1) <br />shall demonstrate compliance with “infrastructure” plan <br />policies in the Downtown Riverfront Specific Area Plan; <br />and, uses proposed pursuant to EC 9.3147(7) and <br />alternatives proposed pursuant to EC 9.3185(4) shall <br />demonstrate compliance with “open space” plan <br />policies in the Downtown Riverfront Specific Area Plan. <br /> <br /> <br />Section 19. <br /> Section 9.8111 of the Eugene Code, 1971, is amended to provide: <br />9.8111 Design Review - Applicability. <br /> [EC 9.3980 allows an applicant within the S-WS <br />Walnut Station Special Area Zone to seek approval through the Design Review <br />process.] Applicants within the S-WS Walnut Station Special Area Zone or S- <br />DR Downtown Riverfront Special Area Zone may seek approval through the <br />Design Review process per EC 9.3980 or EC 9.3190. These applications for <br />review shall be considered under a Type II process, or concurrently with a related <br />Type III application process. No development permit shall be issued by the city prior <br />to completion of the design review. <br /> <br /> <br />Section 20. <br /> Subsection (1) of Section 9.8215 of the Eugene Code, 1971, is amended to <br />provide: <br />9.8215 Partition, Tentative Plan Approval Criteria- General. <br /> The planning director shall <br />approve, approve with conditions, or deny a partition, with findings and conclusions. <br />Approval, or approval with conditions, shall be based on compliance with the <br />following criteria: <br />(1) <br /> The proposed partition complies with all of the following, unless specifically <br />exempt from compliance through a code provision applicable to a <br />special area zone or overlay zone: <br />(a) Lot standards of EC 9.2000 through 9.3915 regarding applicable parcel <br />dimensions and density requirements. Within the /WR Water Resources <br />Conservation Overlay Zone or the /WQ Water Quality Overlay Zone, no <br />new lot may be created if more than 33% of the lot, as created, would <br />be occupied by either: <br />1. The combined area of the /WR conservation setback and any <br />portion of the Goal 5 Water Resource Site that extends landward <br />beyond the conservation setback; or <br /> 2. The /WQ Management Area. <br />(b) EC 9.6800 through EC 9.6875 Standards for Streets, Alleys, and Other <br />Public Ways. <br />(c) EC 9.6500 through EC 9.6505 Public Improvement Standards. <br />(d) EC 9.6706 Development in Flood Plains through EC 9.6709 Special <br />Flood Hazard Areas - Standards. <br />(e) EC 9.6710 Geological and Geotechnical Analysis. <br />(f) EC 9.6735 Public Access Required. <br />(g) EC 9.6750 Special Setback Standards. <br />Ordinance - Page 7 of 12 <br /> <br />