HomeMy WebLinkAboutORDINANCE NO. 9123rt ~,~%
~~
oRDlrrArrc E rro . 9123
1
1
1
tin Ordinance Amending Ordinance Aio. 9013 entitled "An Ordinance providing for the
t
protection of the Public jlealth, and the Registration and Bonding of Persons Engaged in
I
the Business of Plumbing, or Laboring at the Trade of Plumbing; ?~.equiring a Permit .for i
the installation or Alteration of Ylumbin~ and :Drainage Systems; creating the office of ~
i
Plumbing Inspector, and Prescribing his Duties, Defining Certain Terms; Establishing
~I
Minimum Regulations for the Installation, Alteration or Repair of Plumbing and Drainage
Systems and the Inspection Thereof; Providing Penalties for the Violation and Repealing
Conflicting Ordinances." passed by the Common Council on the 9th day of June , 1917,
and approved by the R4ayor on the _lOth day of June , 1g1~7, by omitting certain pro-
j~ visions therefrom with reference to the type of pipe vrhich may be used and by adding a
~II
~I new section numbered Article 7, Section 2a, and declaring an emergency. 'i
~,
~~
'~ THE CITY OF EUGEPJE DOES ORDAIPt AS FOLL01~: '
~i
~~ .Section 1. That, Ordinance No. 9'al3 entitled '+An Ordinance providing for the pro-
I; i
tection of the Public ~iealth, and the Registration and Bonding of rersons Engaged in the ~
II Business of Plumbing, or Laboring at the Trade of Flumbin Requixin a Permit for the
g~ g
i
Installation or Alteration of Plumbing and Drainage Systems; Creating the office of
I~ Plumbing Inspector, and Prescribing his Duties, Defining Certain Terms; Estab]ishing
~~
~~ Mi_nir.!um Regulations for the Insta]lation, AJ_terati on or Repair of Plumbing and Drainage
i
ij :Systems and the Inspection Thereof; Providing Penalties for its Violation and Repealing
I
f Conflicting ~rcli_nances ." passed by the Common Council on the 9th day of June , 1g1t7,
~I ~
~ and a}-.proved by the Ivfayor on the 10th day of June, lgt~7, be, and the same is hereby,
t
~I amended by adding thereto a nevr Section entitled Article 7, Section 2a, vrhich shall read
I' as follows:
~ Section 2a. A shutoff valve shall be placed in cold vrater supply lines to water
~, heaters, and a suitable relief valve installed between the shutoff valve and the range
i
boiler. ~
~I
~I And is further amended by omitting certain portions of various Sections of the gen-
~~ i
~ oral regulations set forth in said Ordinance so that the following numbered Articles '
{ and Sections sha 1]. read as follows
I~ ARTICLE LG
~~
Section J1. Ylaste PIFE NOT BE CONP~Tf:CT TO BEPIDS, "Y" FITTITIC~S TO BE PLACED. No '
P ~I
waste pipe shall be connected to a bend or stub. A "Y" fitting ma~T be placed in a hori-
zontal position between a toilet bend or toilet stub, and the stacR; or vent pipe serv-
I
i
I ing the toilet for a vraste connection, the waste pipe connected thereto shall not exceed
f' 'i
more than twelve (12) feet horizontally, and in no case shall such a waste pipe be more
than two (2) inches in diameter.
{
~ I
1 i
~i
,;
~,
J
rs
i.
,~
Section 15. THREADED FI'I'TIl`IGS: (a) P7_ain screvred fittings for use with wrought ~~
i
~ iron or steel pipe vents may be of cast iron, or of galvanized iron, of standard weights ~~
and dimensions. (b) Screwed drainage fittings for use on soil waste, or leaders shall
be of the recessed drainage type, with smooth interior. waterway, and with threads tapped
out of solid metal. (c) All screwed fittings on water supply pipes shall be either brass
or malleable . (d) All malleable iron fittings shall be galvanized. (e) American Stand-
and pipe thread shall be used on all threaded fittings.
Sect3_on 18. FLOOR FLANGES FC?R V~TATER%~CL05ET5. Floor flanges for water-closets shall be
not less than three-sixteenths of an inch thic}:, if of brass. If of cast iron, flanges shall
be full 3/II inch thick, drilled and .tapped for 1/l~, inch threaded brass rod.
ARTICLE 5.
Section 9. Slipjoints are permitted on either side of traps if not concealed. Unions
on the s ewer side of traps shall be ground and faced, and shall not be concealed.
Section 11, CONPIECTIONS V~TITH TOILETS SLOP SIPIKS. Every toilet, slop sink, pedestal
urinal or similar fixture hsving a trap outlet above the floor shall be securely connected
to the soil or waste pipe by a heavy flange of either brass or iron. The flange shall be
securely fastened to the soil or waste pipe by a caulked, screvred or soldered joint and
the future connected to the f]_ange by means of dravrn brass bolts tapped into the flange
of a diameter of not less than one-quarter (4) of one (1) inch. The joint betvyeen tkie fix-
ture and the flange shall be made gas and vratertight by means of asbestos, graphite gaskets
•~
~, or with putty paste. The use of rubber washers for arty such connection is expressly for-
I _
j bidden. The foregoing provisions, hovrever, shall not be taken as prohibiting in such
joints the use of metal to metal connection or of a screw connection. 1~lall toilets shall be
~ exer~ipted from the provisions of this section, but shall be connected by and vrith approved
I wall toilet hangers and connections.
Section 12. INCREASERS ATm REJUCF,FtS. 1TThere different sizes of pipe or pipes and fit-
s
zings are to be connected, proper size tapered increasers or reducers, shall be used.
Section 15. P1EP1 D,3ATERIALS. The enumeration or specification of certain materials
and practices in this ordinance shall be interpreted as approvirig other materials and
practices not enumerated acid specified herein which are proved by scientific tests .or by
experience to be the subs tantia.l equivalent of the requirements of this code . Any other
material than that specified in this code, vrhich proper administrative authority approves
as being equally efficient, may be permitted.
ARTICLE 11
Section 1. P1IATERIAL. All main or branch soil and vraste pipes within the building shall
be off' cast iron, lead or galvanized wrought or steel pipe, except that no galvanized steel
or wrought iron pipe shall be used for underground soil or vraste pipes or in building over
~ four stories in height .
1
1
1
~~
Section 2. All main or branch vent pipes within the building or structure shall
be of-cast iron, lead, galvanized wrought or steel pipe, except that no wrought iron
or steel pipe shall be used for vent pipe below the ground or basement floor level,
or in buildings over four stories in height.
- ARTICLE 12
Section 3. CO^:PTECTIOAJS +dITH SEPTIC TAPdKS. mien a sevrer is not available, drain
pipes from buildings shall be connected vrith septic tank of approved design.
Section 1~. IJA?IFORP~2 VERTICkL b^tASTES AP?D VEPJTS FOR HIGH BUILUII~1rS. A vertical soil
1
stack or waste pipe and vent stack or vent pipe of uniform diameter may be used in a
high building; of four {I~) or more stories =i.n height, provided the fixtures connected
thereto be located on floors irimediately above each other. The vent shall be con-
nected to the soil stack or vraste pipe by the means of a ~~Y!~ fitting, placed belovr
the waste opening for the lowest fixture, the vertical vraste and vent p~.pes shall be
extended full size through the roof; or be connected together at least six (6) inches
above the r•im of the highest fixtures. The minimum diameter of a vertical vent when
serving six (6) unit fixtures shall not be less than three (3) inches in diameter in
a building not over seven (7) stories in height and four (1t) inches in diameter in a
building over seven (7) stories in height. All offsets or changes in direction in
vertical stacks or wastes in high buildings as provided for in this section shall be
constructed and installed in a manner so as to have not less than aforty-five (!~5)
degree angle. Vlhen a vertical waste pipe line smaller than four !u) inches in diameter,
serves fixtures on four (L~) or more floors, then the horizontal line extending from
the bass of the waste pipe line to the building drain or soil stack, shall be in-
creased to the next size larger. All soil, vraste and vent pipes i.n buildings over
four stories in height, shall be of cast iron pipe, or lead pipe. For the number of
fixture units permitted on uniform vertical waste and, vent, see the table in Article
12, Section 8.
Section 7. P:~'~TERIAL. (a) The house sevrer beginning 5 feet outside of the inner
face of the building wall shall be of cast iron or other approved materials; (b)
The house drain when undergrol~nd shall be of lead or cast iron; (c) The house drain
when above ground shall be of cast iron, galvanized wrought iron or steel, or lead.
ARTICLE 17
1
Section 3. 1TJherever water flush toilets are installed outside the sewer district
the vrastes from such toilets shall be discharged into an approved 500 gallon septic
tank provided vrith adequate facilities for the disposal underground of all effluent
from the septic tank, via sub-surface irrigation.
Passed by the Common Council
this 2 `Lnd day of P~~ rch, 1918
/s/ Henry F. Beistel
i .eear er
Approved by the mayor this
23rd day of ~~arch, 19It8.
/s/ Earl L. ~cPlutt
ayor