Laserfiche WebLink
SECTION 5 - AS -CONSTRUCTS <br />5.00 INTRODUCTION <br />As -constructs (aka, as-builts, record -drawings) superimpose the approved design drawings <br />with what was actually constructed; any divergence between the two must be documented <br />as described below. As -constructs are required for all public improvement projects and must <br />adhere to the drafting standards in Section 3 of this manual and the following requirements. <br />5.01 SUBMITTAL REQUIREMENTS <br />A. Paper Copy <br />One reproducible (high-quality images, text and paper) copy of the as -constructs shall be <br />submitted. <br />B. Electronic Copy <br />The City requires Privately Engineered Public Improvement (PEPI) contractors to submit <br />electronic Computer -Aided Design (CAD) as -construct files with their final drawings. At a <br />minimum, the electronic CAD drawings must delineate control points, light poles, sewer <br />and storm system and curb lines. The CAD files must be provided in State Plane <br />coordinates, the layer naming convention must conform to those used by the City and the <br />CAD file type must be compatible with the City's software. <br />The coordinates of the CAD file map features (e.g., storm lines) must be in Oregon State <br />Plane Coordinates 83/91 South Zone measured in international feet. The origin of the <br />coordinates shall be stated. Vertical datum shall be NAVD88 measured in US survey foot. <br />The benchmark used for the basis of elevations shall be stated. The horizontal and vertical <br />map features must be accurate to 0.10 foot. <br />The layer names in the PEPI CAD files must conform to those used by the City. The DVD <br />provided with the PIDS manual contains an AutoCAD City of Eugene As -Const <br />Template.dwg drawing file. This file contains all the standard layer names and may be <br />used as a template. Listed below are the standard City layer names, in parenthesis, for <br />the minimal delivery. <br />The electronic as -construct submittals will be on DVD and in AutoCAD DWG format. <br />Contact the City for information on the acceptable releases of AutoCAD. Other formats <br />may be considered if they can be imported into AutoCAD or ArcView. All revisions to the <br />original CAD drawings must be incorporated into the electronic submittal. All CAD files of <br />as -construct drawings must conform to the layering names provided in the drawing <br />template provided in the PIDS manual. <br />Public Improvement Design Standards Manual, 2016 5 - 1 <br />