Laserfiche WebLink
<br />Biosolids facilities at the WPCF and the BMF are both sized and function to treat the BOD <br />and TSS removed during the treatment process; therefore, their allocation is split equally <br />between BOD and TSS. <br /> <br />. BOD-l/2 <br />· TSS-l/2 <br /> <br />Tertiary Filters <br /> <br />The existing WPCF does not have tertiary filters. The 20-year project list recommends that <br />'tertiary filters be installed to enable the WPCF to consistently meet the NPDES permit <br />discharge requirements. The permit includes mass limits for BOD and TSS. As influent <br />flows to the WPCF increase in the future,.the effluent concentration required to meet the <br />mass limits decreases. Addition of the filters will assist with meeting these mote stringent <br />effluent concentrations. From a functional basis, the main purpose of the filters is to remove , <br />TSS, and to a lesser degree BOD. Prom a design criteria sizing basis, average flow is used to <br />determine the size of the facilities. In the wet weather season; a portion of the peak flow <br />may be routed to the filters for additional treatment. However, the associated peak flow <br />loading rate onto the filters will not be the limiting factor in terms of design criteria sizing. <br />Following is the allocation for the tertiary filter treatment category: <br /> <br />. Average Flow -1/4 <br />. BOD -1/4 <br />. TSS-1/2 <br /> <br />Reuse Facilities <br /> <br />Reuse facilities may be constructed to comply with more stringent regulatory requirements <br />related to temperature and/ or thermal load restrictions of Willamette River discharges. <br />Reuse facilities would allow flow to be diverted from the river by reusing plant effluent for <br />irrigation. The basic design criterion used to size reuse facilities is average flow; so this <br />parameter receives 100 percent of the allocation. <br /> <br />. Average Flow - 100 percent <br /> <br />Odor Control <br /> <br />Odor control facilities function by collecting odorous air from preliminary / primary liquids <br />treatment processes and biosolids treatment/handling processes and treating the air to <br />remove the odors. Odor generation is dependent on the influent loading levels and, <br />therefore, the allocation is split equally between BOD and TSS because both parameters <br />contribute to the sizing and function of the odor control systems. <br /> <br />. BOD-l/2 <br />. TSS-1/2 <br /> <br />Peak Flow Management <br /> <br />There are a number of future capital improvement projects that specifically function to <br />convey, treat, and discharge the wet season peak flow. For example., th~ parallel <br />primary / secondary peak flow management approach is proposed solely to address peak <br /> <br />A-25 <br />