My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
Ordinance No. 19498
COE
>
City of Eugene
>
Ordinances
>
1980s No. 18550-19659
>
Ordinance No. 19498
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
6/10/2010 3:45:05 PM
Creation date
2/25/2009 1:57:36 PM
Metadata
Fields
Template:
Council Ordinances
CMO_Document_Number
19498
Document_Title
Adopting the Int'l Conf. of Building Officials' & Western Fire Chiefs Assoc.'s Uniform Fire Code, 1985 edition, with certain modifications, additions & deletions; amending 8.001, 8.010, 8.190 & 8.200; adding 8.205 & repealing 8.020 & 8.195.
Adopted_Date
9/14/1987
Approved Date
9/14/1987
CMO_Effective_Date
10/15/1987
Signer
Brian B. Obie
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
16
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
a. The existing structure does sat constitute a <br />life or safety hazard to its occupants; or <br />b. The existing structure is not remodeled, in any <br />single calendar year, to the extent of mare than 25 per- <br />cent of its market value immediately prior to remodeling. <br />At such time as an existing structure other than a <br />Group R occupancy is deemed by the building official to <br />present a life or safety hazard to its occupants or is <br />remodeled to the extent of more than 25 percent of its <br />market value, an approved automatic fire extinguishing <br />system shall be installed throughout, including the base- <br />ment. <br />3. Existing Group R occupancies shall comply with sub- <br />section ~1} abave•except that Group R occupancies in substan- <br />t~ al compl ~ once with al 1 present codes, and equipped with <br />smokeproof towers, combination standpipes, and supervised fire <br />alarms with manual pull stations, upon recommendation of the <br />fire marshal and approval of the Structural Specialty Code <br />Beard of Appeals, may be permitted to install a less extensive <br />sprinkling system, protecting only the exit system of the <br />bu~ld~ng, ~n lieu of the other requirements of this section. <br />The exit protection system must include automatic s rinklers <br />~n all exit wa ' p <br />. ys, an automatic sprinkler head in each ~nd~v~- <br />dual 1~v~ng unit, and a nationally recognized testis labvra- <br />tar -a roved batt g <br />. Y pp . •ery or electrically operated smoke detector <br />~n each living unit. Sprinkler heads within living units <br />shall be located no closer than four ~4} and no further than <br />six ~6} feet from the corridor door. Side wall mounted s rink- <br />ler heads ma be used w' ~ p <br />Y ith~n 1~v~ng units ~f the spray from <br />such heads will completely cover the door area to be rotected. <br />17 Section 10.311 of p <br />~ } the Uniform Fire Code ~s amended tv add: <br />~f} Location of Combination Stand i e S stem. A combination <br />standpipe shall be provided for each stairway or smoke- roof enclo- <br />sure which extends p <br />from the top floor to the ground story in <br />buildings four or mare stories in height. Combination stand i e <br />s stems shal] have o p p <br />Y, f utlets so located that all portions of the <br />bu~ld~ng and all rooms and other spaces are within 20 feet of the <br />nozzle attached to 104 feet of hose. <br />~1} Size. Combination standpipe systems shall be not <br />less than four inches in diameter in buildings in which the <br />highest outlet is less than 75 feet from the fire de artment <br />connection n p• <br />a d shall be not less than six inches in diameter <br />where the highest outlet is 15 feet or mare above that c~nnec- <br />tion. <br />~2} Construction and Testis . Fittings and connections <br />shall be of sufficient strength to withstand 300 pounds of <br />water pressure per square inch when ready for service. All <br />camb~nat~on standpipes shall be tested hydrostatically to with- <br />stand such pressure for two hours, but in no case shall the <br />pressure be less than 50 pounds per square inch above the <br />maximum working pressure. <br />~3} Riser shut-Off valve and drain. Each individual <br />riser shall be equipped with an OS and Y valve at its base <br />Ordinance - 7 <br />
The URL can be used to link to this page
Your browser does not support the video tag.