Ordinance concerning the Uniform Fire Code; amending Sections 8.190 and 8.200 of the Eugene Code, 1971; and declaring an emergency.
Adopted_Date
1/23/1989
Approved Date
1/23/1989
CMO_Effective_Date
1/23/1989
Signer
Jeffrey R. Miller
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
104
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Maximum Quantity per <br />Building Tans} 100 300 No Limit <br />FN 1. Except in buildings used far retail sales, quantity <br />limits per pile and per building may be doubled where <br />Class 3 oxidizers are in noncombustible containers. <br />FN 2. Quantity limits per pile and per building shall be re- <br />duced by 50 percent in buildings or portions of build- <br />ings used for retail sales. <br />FN 3. Aisle width shall equal pile height. <br />Table 8D.306-H <br />STORAGE OF CLASS 4 OXIDIZERS IN DRUMS, CONTAINERS, CASES <br />Condition Maximum Feet <br />Piles _ <br />Length <br />Width <br />Height <br />Distance to next pile <br />Maximum Quantity per Building Tons} <br />IO <br />4 <br />8 <br />8 <br />No Limit <br />C. Lvcatian in Buildin . The storage of Class 2 <br />oxidizers sha11 not be permitted in basements except when <br />storage is in stationary tanks. Class 3 and 4 oxidizers <br />in excess of the exempt amounts specified in Table <br />80.306-A shall be stored an the ground floor only. <br />13 . Seurat i on . <br />A. In addition to the provisions of Section 80.301 n <br />~~ <br />Class 3 and 4 oxidizers shall be separated from other <br />hazardous materials by not less than one-hour fire- <br />resistive construction or stored in hazardous materials <br />storage cabinets. <br />B. Detached storage buildings for Class 4 oxidizers <br />shal 1 be 1 ocated a mi n i mum of 50 feet from al 1 other <br />hazardous materials storage. <br />14. Contamination. Oxidizers shall not be stored on or <br />against combustible surfaces. During storage, care shall be <br />taken to prevent contamination <br />€b~ Exterior 5tora e. <br />1. General. Exterior storage of liquid and solid oxi- <br />dizers shall be in accordance with the previsions of this sub- <br />section and the general provisions specified in Section 80.301. <br />Z. Distance from Story e to Ex osures. Storage areas <br />for oxidizers shall be located in accordance with Tables <br />80.306-C and 80.306-D. <br />3. Story a Conditions - Maximum Quantities. The maxi- <br />mum quantities of C1 ass 4 oxidizers shall be as specified in <br />Table 80.306-D. <br />4. Storage Arran ement. Sha11 be as specified in <br />Tables 8D.30fi-E through 80.3ofi-H, <br />Section 80.301 - Hazardous Materials, Or anic Peroxides. <br />~a~ Indoor Story e. <br />1. General. Indoor storage of organic peroxides shall <br />Ordinance - 43 <br />