My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
Ordinance No. 19593
COE
>
City of Eugene
>
Ordinances
>
1980s No. 18550-19659
>
Ordinance No. 19593
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
6/10/2010 3:45:41 PM
Creation date
3/3/2009 1:16:20 PM
Metadata
Fields
Template:
Council Ordinances
CMO_Document_Number
19593
Document_Title
Ordinance concerning the Uniform Fire Code; amending Sections 8.190 and 8.200 of the Eugene Code, 1971; and declaring an emergency.
Adopted_Date
1/23/1989
Approved Date
1/23/1989
CMO_Effective_Date
1/23/1989
Signer
Jeffrey R. Miller
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
104
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
shall be single-story buildings, without basement or crawl <br />space, and of non-combustible construction. <br />Table 80.307-8 <br />REQUIRED DETACHED STORAGE OF ORGANIC PEROXIDES <br />Class Detached Stora a Re wired When Amount Exceeds Tons <br />UD* See Article 77 <br />I Exempt Amount Specified in Table 80.3D1-A <br />II 25 <br />III 50 <br />IV & V ND Requirement <br />*Uncl ass i f i ed Detanatabl e <br />4. Distance from Detached Stora a Buildin s to Ex osures. <br />In addition to the provisions of the Structural Specialty <br />Cade, detached storage buildings shall be located in accord- <br />ance with Tables Nos. 80.301-C and 80.307-D. <br />Table 80.307-C <br />SEPARATION OF DETACHED STORAGE FROM OTHER BUILDINGS, PROPERTY <br />LINES, STREETS, ALLEYS, PUBLIC WAYS OR EXITS TO A PUBLIC WAY <br /> Maximum Storage Quantity ~Pounds~ <br /> at Minimum Se oration <br />Class 50 Feet 100 Feet 154 Feet <br />I 2,000 20,OOD 175,000 <br />II 100,000 200,OOD Unlimited <br />III 200,000 Unlimited Unlimited <br />IV Unlimited Unlimited Unlimited <br />Table 80.307-D <br />SEPARATION BETWEEN <br />Class <br />I <br />II <br />III <br />IV <br />AS: <br />NS: <br />FN 1. <br />Prnte~tinn <br />INDIVIDUAL DETACHED STORAGE BUILDINGS <br />OR AREAS <br />Maximum Storage Quantity Pounds} <br />at Minimum Separation [Feet) <br />20 Feet 75 Feet 100 Feet <br />~~ ~ , 000 ~ 4, aoo 10, 000 <br />AS 2, 000 20, 000 115, 000 <br />--------------.. Footnote 1 _-_____----__---..___-_ <br />--------------- Footnote 1 --_____----_..___..___-- <br />------..---_---- Footnote 1 ---------------------- <br />Automatic sprinkler system protection provided. <br />No sprinkler system protection. <br />When the amount of organic peroxide stored does not <br />exceed the amount indicated in Table 80.307-C, minimum <br />separation shall be 20 feet; when the amount or organic <br />peroxide stored exceeds the amount indicated in Table <br />80.301-C, minimum separation shall be 5o feet. <br />5. Li uid-Ti ht Floor. In addition to the requirements <br />of Section 80.301~z}, floors of storage areas shall be of <br />Ordinance - 45 <br />