18743 <br />~_8~ Subdivision 2.A, of Subsection 3502 ~b~ , Where <br />Required, is hereby amended to read: <br />2. Group A occupancies. <br />A. Tn basements and cellars of more than <br />1,500 square feet in floor area, and as required <br />by the fire code as amended by section 5.204~7y <br />Cgs of the Eugene Code, 1971. <br />~9~. Subdivision 3.A, of Subsection 3802 ~b~ , Where <br />Required; is hereby amended to read: <br />3. ~ Group E occupancies . <br />A. In basements and cellars of more than <br />I~500 square feet in floor area, and as required <br />by the fire code as amended by section 8.200~7~ <br />~g ~_ o f the Eugene Cade , 19 71. <br />l0 . Subsection.~~ 3,,,8,_~,_,_b~,, Where,.,,,,,,R,equired, is hereby <br />amended by adding a subdivision 8. Group R occupancies, Except <br />Group R, Division 3, and Grou M, to read: <br />8. Grou R Occupancies except Group R, Division <br />3, and Gro~~ M. <br />A. For Group R occupancies, the provisions <br />in Subdivision 1. F, of Subsection 3802~b~ shall <br />not apply to existing structures so long as the R <br />occupancy is in substantial compliance with all <br />present codes, and equipped with smokeproof towers, <br />combination standpipes, and supervised fire alarms <br />with manual pull stations. Upon recommendation of <br />the fire marshal and approval of the Structural <br />Specialty Code Board of Appeals Group R occupancies <br />may be permitted to have a less extensive sprinkler <br />system protecting only the exit system of the <br />building, in lieu of other requirements of Subsec- <br />tion 3S02~b~. The exit-protection must include <br />automatic sprinklers in all exit ways, automatic <br />sprinkler heads in each individual living unit, <br />and an approved battery or electrically operated <br />smoke detector in each living unit. Sprinkler <br />heads within living units shall be located no clos- <br />er than four feet and no further than six feet <br />from the corridor door. Side-wall mounted sprink- <br />ler heads may be used within a living un~.t if the <br />spray from such heads will completely cover the <br />door area to be protected. <br />B. Smoke detectors shall be governed by <br />Subdivision 1210 ~.a}. 2. <br />~11~ Subsection 3803 ~..a~, General, is hereby amended to <br />read <br />~a~ General. Standpipes shall comply with the <br />requirements of this section and with NFFA No. 13, <br />1978 edition, as adopted and copyrighted by the National <br />Fire Protection Association. Standpipe systems are <br />classified as follows: <br />Ordinance - 7 <br />