My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
Resolution No. 4793
COE
>
City of Eugene
>
Resolutions
>
2004 No. 4782-4819
>
Resolution No. 4793
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
6/10/2010 4:49:14 PM
Creation date
7/7/2004 4:37:39 PM
Metadata
Fields
Template:
City Recorder
CMO_Document_Type
Resolutions
Document_Date
6/28/2004
Document_Number
4793
CMO_Effective_Date
6/28/2004
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
322
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
5 BASIS OF PLANNING <br /> <br />5,4.2 Liquids Treatment Facilities Design <br />The 2025 design criteria for flow at the WPCF are summarized in Table 5.4.2-1. These flows . <br />provide the basis for future hquids unit process design. <br /> <br />TABLE 5.4.2-1 <br />Summary of Total Flow Projections For 2025 (Residential, Commercial, and Industrial) <br />MWMC Facilities Plan, Eugene-Springfield <br /> <br /> Year 2025 <br />Estimated Population 297,585 <br />Wastewater Flow Projections (mgd) <br />Max. Month Dry Weather 59.3 <br />Max. Month Wet Weather 110.8 <br />Peak Day Wet Weather 227 <br />Peak Hour Wet Weather 277 <br /> <br />Table 5.4.2-2 summarizes the anticipated 2025 facility needs, design basis, and condition <br />requirements for each 1/quids unit process based on reliability and redundancy <br />requirements. <br /> <br />TABLE 5.4.2-2 <br />L~quids Unit Process, Existing and 2025 Design Capacity <br />MW/ftC Factlities Plan, Eugene-Springfield <br /> <br /> Existing Total 2025 Capacity <br /> Design Capacity Need <br /> Unit Process Basis (mgd) (mgd) 2{:)25 Condition of Need <br /> <br />Infiuent Pumping PWWF 215 277 Firm capacity without largest unit out <br /> of service <br /> <br />Influent Screening PWWF 175 277 Firm Capacity with one unit out of <br /> service <br />Grit Remova~ PWWF 175 277 Firm Capacity with one unit out of <br /> service <br />Preaeration AWWF 58.4 No Additional None <br /> Capacity Need <br /> <br />Primary Clarification PWWF 86 277 or 160 with 50% of design flow capacity w~th <br /> flow management largest out of service <br /> <br />Aeration Basins ADWF 49 59 Total Capacity <br /> AWWF 75 111 Total Capacity <br /> <br />Secondary ADWF 49 59 75% of design flow capacity with <br />Clanfication largest out of service <br /> <br /> AWWF 75 111 <br /> <br /> MWMC_5.0_REVS._VKS,DOC 5-27 <br /> <br /> <br />
The URL can be used to link to this page
Your browser does not support the video tag.