<br />41-9 <br />not more than 1 gallon capacity, a.nd not exceeding <br />~, tot?1 of 10 gallons . <br />Class 11. In sealed metal containers of not more than <br />5 gallons ca.pa.city and in barrels, drums or tanks not <br />exceeding 60 gallons c~pa.city (total quantity stored un- <br />limited). <br />C1.ass 111. In sealed containers not exceeding 5 gallons <br />capacity, in barrels and. drums and in tanks not exceeding <br />120 gallons c~:.pacity, except as permitted in Section 960 <br />(total quantity stored in this manner unlimited). <br />In other than frame buildings: <br />Class 1. Not exceeding 50 gal-lops in sealed containers <br />or safety cans of not more than 1 gallon capacity. <br />Class 11. In sealed metal containers or safety cans of <br />not more than 5 gallons capacity, in drums and barrels <br />and in tanks not exceedint 120 gallons capacity (total <br />quantity stored in this manner unlimited). <br />Class 111. In sealed containers, drums and barrels and <br />in tanks-not exceeding 240 gallons capacity, except as <br />permitted in Section 960 (total quantity stored in this <br />manner unlimited). <br />014 STOP,AGE RESTP:ICTIONS FOP BT,?II,DIT:GS USED FOR STOa?AGE OSt DATE OF <br />FNACTI~~ENT OF ORDINANCE <br />In buildings no~n~ used for storage of fla.mma.ble liquids, <br />the storage (except in speeia.l rooms as given in Section 915) shall <br />not exceed double the nuantity specified in Section 91j. (Ca.pacity of Ind.ividua.l <br />tanks or containers may be double that specified in Section`91j. <br />91 SPECIAL STOP.AGE R002~IS OR BUILDINGS. <br />Special rooms or buildings for storage of flammable liquids and. the <br />handling and. use of flammable liquids shall, u~here called for by other sections of <br />this ordinance, be constructed as follows; provided however that when in the <br />opinion of the Chief of the Bureau of Fire Prevention the ,extent of the hazard formed <br />is more than moderate, based upon a consideration of the quantity and nature of <br />flammable liquids involved. and the extent of mixing operations together ~r*ith the <br />character of construction, of the building in tr~hich the proposed storage mixing <br />operations are to be lc c..-,ted, and of exposed buildings, construction affording a, <br />greater degree of protection shall be required. <br />~ra11.s shall have a fire resistance rating of not less than one hour; they <br />sh~11 be contincus from floor to ceiling and shall b e securely anchored. <br />Ceiling shall be of construction equ~~alent to not, less than j~~inch of <br />gupsum plaster on metal lath. <br />Floors if of wood sha.1.1 be protected with not less than 2 inches of concrete. <br />Door openings to other rooms or buildings shall be provided with non- <br />combustible si11.s raised 6 inches. Sn.ch openings shall be protected by standard <br />fire doors of approved automatic or self closing type. <br />''here other portions of the building or other properties are exposed., ~••indo*h~s <br />stall be protected in a standard manner. <br />Shelving shall be non-combustible <br />STORAGE OF CLP.LL L LI~;~i1IDS. <br />Except ~r~her.e kept in sealed metal containers, 61ass 1 Liquids shall be <br />kept in storage tan'_•cs undegground or outside the building and no discharge <br />system shall have outlet inside building unless in a special room in ai:cord.ance <br />with Section 915. Safety cans of not over 10 gallor_s capacity may be used in a.ny <br />part of buildings except that if of over one gallon capacity, they shall be kept <br />a.nd used in special rooms in accordance trrith Section 915. <br />In garages and manufacturing plants the Chief of the Bureau of Fire <br />Prevention may permit the storage of Class 1 liquids in ap~oroved portable ~r~heeled <br />tanks, ~,~here the nature of the business requires such storage and the discharge <br />therefrom. <br />