Laserfiche WebLink
4~0 <br />Part ~. <br />NI?'OR_rFt t,UI.,O~~' MOTION PI<CTURF FILP~I <br />u01 It shall be a misdemeanor fcr ~,ny person, firm or corpora+ion to sell <br />any toy or minature motion -picture machine containing nitro-cellulose motion picture <br />fifim, or to sell, lease or othertaise dispose of any y~.itro-cellu7_ese meticn picture <br />fi.l.ms to any' person not ?1~ving a Hermit to handle, use ~r display such film. <br />li02 A permit shall be required for the storage of nitro-cellulos? motion <br />picture film in quantities greater than five ree'__s, or aggregating more thwn 25 <br />pounds of weitht, No permit shale. be issued for any building unless the reons in <br />~rrhich film is handled or stored are protected by automatic sprinklers; provided <br />that this does not include ~orojection booths covered. in Section X05, <br />~. ~TOpAGE Nitrocellulose r.!oticn pictrzre film in other than the original <br />shipping casPS conforming to interstate 8ommerce Com:~issions regulations, in amounts <br />in excess of 25 pound$ but not in•excess.of 1,000 pounds lshall be kept in approved <br />~, cabinets if not in baults; amounts. `in excess of 1,000 pounds shall be kept in <br />vaults• _ <br />I Note: The standard ro]~1 of film 1 3~g inches (3.5mm,) raids and 1,000 <br />feet long weighs about ~ pounds. <br />1 <br />t lip~+ FLTKii CABU$ETS ^~BD VAULTS, <br />(a) Cabinets shall be of approved construction and shall pct have a <br />j capacity in excess. of 375 pounds of film. <br />{ (b) C~?;inets having a capacity of over 50 pounds of film shall be provided <br />i with a vent from each compartment to the outside of the bi:.ilding. The vent shall <br />have a minimum effective sectional area. of 1~' square inches per 100 pounds of film <br />t capacity. be <br />(c) Cabinets holding over 75 pounds of film shall provided with at least <br />one automatic sprinkler; provided that a cabinet constructed so that each roll is <br />~ ir. a separate compartment a.nd will ?urn out without cemmur_~cating fire to film in <br />j any other compartment, need not be provided with an automatic sprinkler. <br />(d) Film va~~tts shell be constructed, vented and s;~rinklPred in acs. JL•dance <br />j ~~,ith the requirements for st~_ndard film vaults and in a manner satisfactory to the , <br />B~,zreau of Fire Prevention. <br />4~ Every picture machine using nitr,o-cellulose film shall be ir_stalled or <br />operated ~~rithin a booth, to be not, less than ~+S square ,feet in size and 7 feet high: <br />If more than one machine is to be operated an additional 2Z- square feet shall be <br />provided for each additional machine. The booth shall be built of brink, tile, or -- <br />plaster blocks, plastered on both sides, or of concrete, or of a rigid metal frame, <br />properly braced, and sheathed a,nd roofed with locked seamed sheet iron of not less <br />than No. 20 U,S, metal gauge, or with '~ inch hard asbEStos board, securely riveted <br />or bolted~to the frame, or 2 inches of-solid metal lath and Portland cement Plaster. <br />All joints aha.ll be sufficiently tight to prevent the discharge of smoke. <br />(, a) The booth shall be floored with the same material as the <br />sides and roof, riveted to the iron frame and covered with the same noncombustible <br />material. The entrance door into the bootie shall be at least 2 feet by 5 feet, <br />of construction equivalent to the sheathing permitted above for rigid frame booths, <br />and shal?_ be so arranged. as to close autom2aically, and shall be kept closed at all <br />times shop not used for egress or ingress. <br />(b) Two or=f ices or openings for each picture machine may be provided <br />one for the operators view shall be not larger than ~6 se~uare inches, and the other <br />through v-hich the picture is projected shall be not larger than o~ scauare inches. <br />Trlhere separate stereopticon, spot of flood light machines are instal7_ed in the same <br />booth frith picture machines, not more than or_e opening for each machine shall. be <br />~orovided for both the operators view and for the projection of the light, but two <br />or more machines may be operated through the same openings; such openings shall be <br />as small as practicable and shall be capable of being protected by approved <br />automatic shutters. Each opening shall be provided with a gravity shutter. of <br />approved fireproof material. Lerch shutter shall hav° a fusible link above it, <br />and there shalt also be one located over each upper projector magazine v+hich, <br />upon operating, grill close all the shutters, Trere shall also be provided <br />suitable means for manually closing atl shutters~simultaneous?y fron a point near <br />the door. Shutters on openings not in use shall, be kept closed. <br />~'c) A11 shelves, furniture and fixtures within the booth shall be <br />constructed of incombustible material, and no combustible material of any sort <br />Trrhatever shall be permitted err a.llo~,re to bz within such booth, except the films <br />used in the oper.?.tion of the machine, and film ce,-~ent. <br />All picture machines using inflamr-i~ble fii_ms shall re equipped vrith <br />incombustible magazines for rrceiving ~,nd delivering the films during the <br />operation of the machine. A shutter must be provided and placed in front of the <br />condensor of the machine, so arranged that same can be instantly closed by the <br />operator. <br /> <br />