Laserfiche WebLink
alterations, and change of use group classifications conforms to land use regulations <br />and the structural specialty code. The plans and specifications must be complete <br />and shall show, among other details, the following: <br />2.4.1.1. Scaled plot plan showing the location of all new <br />construction and all existing structures on the site, including parking areas <br />and drives, dimensions of lot and buildings, and distance from lot lines, <br />drawn in accordance with an accurate boundary line survey. <br />2.4.1.2. Scaled floor plans showing the structure's layout (rooms), <br />room dimensions, and areas labeled as to intended use, location, and sizes <br />of doors and windows. <br />2.4.1.3. Structural plans showing framing and other support and <br />load -carrying structural features, including foundation plan, floor and <br />ceiling roof system construction with adequate dimensions and labeling of <br />materials to permit a determination of code compliance and structural <br />safety. <br />2.4.1.4. Plans for buildings of more than two stories in height of <br />other than Group R, Division 3 (one- and two-family dwellings) and M <br />occupancies (accessory buildings thereto) shall indicate how required <br />structural and fire -resistive integrity will be maintained where a penetration <br />will be made for electrical, mechanical, plumbing, communication conduits, <br />pipes and similar systems. <br />2.4.2. Electrical Plans. A person making application for an electrical <br />permit on any structure, other than Group R, Division 3 (one- and two-family <br />dwellings) and M occupancies (accessory buildings thereto), shall file with the <br />Building Official proper electrical plans, specifications, calculations, and schedules <br />as may be necessary to determine whether the installation as described will conform <br />to the requirements of the electrical code. The plans and specifications submitted <br />must be complete and shall show, among other details, the following: <br />2.4.2.1. A layout for each floor with dimensions of all rooms and <br />working space, including a legend of all symbols used. <br />2.4.2.2. Size of wire and conduit for main services and approximate <br />location in the buildings of its electrical service, equipment, and heating. <br />2.4.2.3. Main service layout, size, number of main switches, and <br />similar information. <br />2.4.2.4. Location of distribution panels and size of branch circuits <br />and conduit -feeding distribution cabinets. <br />Administrative Order - Page 14 of 40 <br />