My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
Admin Order 52-07-02-F
COE
>
City of Eugene
>
Administrative Orders
>
2007
>
Admin Order 52-07-02-F
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
6/10/2010 10:46:09 AM
Creation date
6/26/2007 12:37:07 PM
Metadata
Fields
Template:
City Recorder
CMO_Document_Type
Admin Orders
Document_Date
6/21/2007
Document_Number
52-07-02-F
CMO_Effective_Date
6/21/2007
Author
Dennis M. Taylor
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
12
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
<br />4. Recreation fires in an approved campsite in fire pits provided for the <br />campsite. <br />5. As permitted by Lane Regional Pollution Authority and Section 6.200 of <br />the Eugene Code, 1971. <br /> <br />11. Section 901.5 of the OFC is amended to provide: <br /> <br />901.5 Installation acceptance testing. Fire detection and alarm systems, fire- <br />extinguishing systems, fire hydrant systems, fire standpipe systems, fire pump <br />systems, private fire service mains, smoke and heat ventilators, smoke-removal <br />systems, hazardous materials protection and detection systems, and all other fire <br />protection systems and appurtenances thereto shall be subject to acceptance tests <br />as contained in the installation standards and as approved by the fire code official. <br />The fire code official shall be notified before any required acceptance testing. <br /> <br />12. Section 901.6 of the OFC is amended to provide: <br /> <br />901.6 Inspection, testing and maintenance. Fire detection and alarm systems, fire- <br />extinguishing systems, fire hydrant systems, fire standpipe systems, fire pump <br />systems, private fire service mains, smoke and heat ventilators, smoke-removal <br />systems, hazardous materials protection and detection systems, and all other fire <br />protection systems and appurtenances thereto shall be maintained in an operative <br />condition at all times, and shall be replaced or repaired where defective. Non- <br />required fire protection systems and equipment shall be inspected, tested and <br />maintained or removed. <br /> <br />13. Section 901.6.1 of the OFC is amended to provide: <br /> <br />901.6.1 <br /> <br />Standards. Fire protection systems shall be inspected, tested and maintained in <br />accordance with the referenced standards listed; <br />a. NFP A 10-2007, Portable Fire Extinguishers <br />b. NFP A 11-2005, Low-expansion Foam <br />c. NFPA 11-2005, Medium- and High-expansion Foam Systems <br />d. NFPA 12-2005, Carbon Dioxide Extinguishing Systems <br />e. NFPA 13-2007, Sprinkler Systems <br />f. NFPA 13D-2007, Sprinkler Systems in One- and Two- Family Dwellings <br />g. NFPA 13R-2007, Sprinkler Systems in Residential Occupancies up to and <br />Including Four Stories in Height <br />h. NFPA 14-2007, Standpipe and Hose Systems <br />1. NFPA 15-2007, Water Spray Fixed Systems <br />J. NFPA 20-2007, Centrifugal Fire Pumps <br />k. NFP A 24-2007, Private Fire Service Mains <br />1. NFPA 72-2007, National Fire Alarm Code <br /> <br />Administrative Order - 7 of 12 <br />C:\Documents and Settings\cefddwp\Local Settings\Temporary Internet Files\OLK2A\_07 fire code - 2 ao (00174830).doc <br />
The URL can be used to link to this page
Your browser does not support the video tag.