operated when installed in existing buildings, in buildings <br />without commercial power, or in buildings which undergo alter- <br />ation, repair, etc., and when such work does not involve the <br />creation of additional units or is a change of occupancy. <br />2. In Grou R Division 1 occu ancies every dwelling <br />unit within an apartment house, and every guest room designed <br />or used for sleeping purposes within a hotel or motel, shall <br />be equipped with an approved smoke detector. Detectors <br />within apartment dwelling units shall be mounted an ceilings <br />or walls in each unit at a point centrally located in the <br />corridor or other area with access to the rooms used for <br />sleeping purposes. In efficiency or studio apartments, and <br />w~th~n hotel and motel guest units, the detectors shall be <br />centrally located on the ceiling or wall. Detectors inside <br />dwelling units or sleeping roams, if awall-mounted detector <br />is used, shall not be less than six inches or more than l2 <br />inches from the ceiling. Where dwelling units and sleeping <br />rooms are on an upper level, additional detectors shall be <br />placed at an accessible location as close as practical to <br />the center of the ceiling directly above the stairways. The <br />owner of each hotel or motel, or designee, shall inspect and <br />service each detector every 12 months. A record shall be <br />maintained for each detector listing the date installed, dates <br />inspected, and dates serviced. This record shall be available <br />for inspection by the fire marshal . The following shall ap ly <br />p <br />to smoke detectors w~th~n apartment house dweli~ng units: <br />a. The building owner or designee shall post <br />written instructions far the operation of the smoke <br />detector within each dwelling unit. <br />b. The tenant of each dwelling unit shall be <br />responsible for periodically testing the unit's smoke <br />detector. The building owner ar designee shall not be <br />responsible if a tenant removes a battery from a <br />detector. <br />c. Upon failure of the detector, the tenant shall <br />deliver a written notice of failure tv the building <br />owner ar designee. <br />d. The owner shall replace or repair the defective <br />detector within ten CIO} days from the date of the <br />notice. <br />3. ~n Group R,_ Division 3 occupancies every existing <br />dwelling that ~s being rent~ed,~leased, or is otherwise being <br />occupied for consideration, and each guest/sleeping room in <br />a lodging house, shall be equipped with an approved detector. <br />Detectors within qualifying buildings shall be mounted on <br />the ceiling or wall at a point centrally located in each <br />corridor or area giving access to rooms used far sleeping <br />purposes. When actuated, the detector shall sound an alarm <br />audible i n each sleeping room. The fol 1 owl ng shal 1 apply to <br />such detectors: <br />a. The building owner or designee shall post <br />written instructions for the operation of the detector <br />in each qualifying dwelling and in each sleeping room <br />Ordinance - 13 <br />