Laserfiche WebLink
pressed gases are stared, a minimum of two ~2~ self-contained <br />breathing apparatus shall be provided. The breathing appara- <br />tus shall be suitable for use with the material stored and <br />shall be located near the immediate area of storage in a loca- <br />tion that provides safety to those expected to don the appara- <br />tus. A safe area is one which is not likely to be immediately <br />affected by the release of hazardous material in the area of <br />concern. A written Respiratory Protection Plan, personnel <br />training, and equipment inspection, maintenance, and record <br />keeping shall be provided in accordance with 29 CFR 1910.134. <br />EXCEPTION: Where self-contained breathing apparatus <br />would be inadequate protection due to the nature of the <br />gases present, other appropriate protective equipment <br />shall be provided. <br />Section 80.304 -Hazardous Materials, Flammable Combustible Ei uids. <br />Storage of flammable and combustible liquids shall be in accordance with the <br />provisions of Article 79. <br />Section 80.305 -Hazardous Materials, Flammable Solids. <br />~a3 Indoor Storage. <br />~1. General. Indoor storage of flammable solids shall be <br />in accordance with the provisions of this subsection and the <br />general provisions specified in Section 80,301. Storage of <br />combustible fibers shall be in accordance with the provisions <br />of Article 28. <br />2. Exem t Amounts. When the amount of flammable solids <br />stared in one control area exceeds that specified in Table <br />80.305-A, such storage shall be within a room or building <br />conforming to the Structural Specialty Code requirements for <br />a Group H, Division 3 Occupancy, or a Group H, Division 2 <br />Occupancy when combustible dusts are stored in piles ar <br />within open containers. <br />Condition <br />Unprotected by <br />cabinet <br />Within cabinet <br />building <br />In sprinklered <br />cabinet <br />In sprinklered <br />cabinet <br />Table 80.305-A <br />sprinklers or <br />i n unspri nkl erect <br />building, not in <br />building, within <br />Exempt Amounts ~paunds <br />125 <br />25a <br />250 <br />500 <br />3. S i l l Control , Drai ns a and Containment. Spi l l con- <br />trol , drainage and containment shall not be required for the <br />storage of flammable solids. <br />4. Ex losion Ventin ar Su cession. Rooms, buildings, <br />or equipment used for the storage of combustible dusts shall <br />be provided with explosion venting or suppression in accord- <br />ance with the provisions of Section 80.301~q~. <br />5. Ventilation. Mechanical exhaust ventilation shall <br />not be required. <br />Ordinance - 38 <br />