Ordinance No. 19593
COE
>
City of Eugene
>
Ordinances
>
1980s No. 18550-19659
>
Ordinance No. 19593
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
6/10/2010 3:45:41 PM
Creation date
3/3/2009 1:16:20 PM
Metadata
Fields
Template:
Council Ordinances
CMO_Document_Number
19593
Document_Title
Ordinance concerning the Uniform Fire Code; amending Sections 8.190 and 8.200 of the Eugene Code, 1971; and declaring an emergency.
Adopted_Date
1/23/1989
Approved Date
1/23/1989
CMO_Effective_Date
1/23/1989
Signer
Jeffrey R. Miller
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
104
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Table 80.307-E <br />STORAGE OF CLASS I ORGANIC PEROxIDES <br />fnnrlitinn I ~m,tc <br />r~ies <br />Width Meet} 6 <br />Height Meet} 8 <br />Distance to next pile <br />~ f eet } 4 ~ FN 1 } <br />Distance to walls Meet} 4 ~FN Z} <br />Maximum Quantity per <br />Building FN 3 <br />FN I. At least one main aisle with a minimum width of 8 <br />feet sha11 divide the storage area. <br />FN ~. Distance to noncombustible walls may be reduced to <br />two feet. <br />FN 3. See Tables 80.301-B and 80.301-C for maximum <br />quantities. <br />Table 80.307-F <br />STORAGE OF CLASS II AND III ORGANIC PEROXIDES <br />fnnrlitinn ~ im,tc <br />riie5 <br />Width Meet} 10 <br />Height Meet} 8 <br />Distance to next pile Meet} 4 <br />Distance to walls Meet} 4 ~FN I} <br />Maximum Quantity per building FN 2 <br />FN I. At least one main aisle with a minimum width of 8 <br />feet shall divide the storage area. <br />FN 2. Distance to noncombustible walls may be reduced to <br />two feet. <br />FN 3. See Tables 80.307-8, 80.307-C and 80.307-D for <br />maximum quantities. <br />Table 80.301-G <br />STORAGE OF CLASS IV ORGANIC PEROxIDES <br />Condition Limits <br />Piles <br />Width Meet} I~ <br />Height Meet} 10 <br />Distance to next pile Meet} ~FN 1} 3 ~FN 1,2} <br />Distance to combusti b1 a wal 1 s Meet} ~ <br />Maximum Quantity per building FN 3 <br />FN 1. At least one main aisle with a minimum width of 8 <br />feet shall divide the storage area. <br />FN ~. Distance shall be not less than one-half the pile <br />height. <br />FN 3. See Tables Nos. 80.301-8 and 80.307-C for maximum <br />quantities. <br />Ordinance - 41 <br />