My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
Ordinance No. 19593
COE
>
City of Eugene
>
Ordinances
>
1980s No. 18550-19659
>
Ordinance No. 19593
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
6/10/2010 3:45:41 PM
Creation date
3/3/2009 1:16:20 PM
Metadata
Fields
Template:
Council Ordinances
CMO_Document_Number
19593
Document_Title
Ordinance concerning the Uniform Fire Code; amending Sections 8.190 and 8.200 of the Eugene Code, 1971; and declaring an emergency.
Adopted_Date
1/23/1989
Approved Date
1/23/1989
CMO_Effective_Date
1/23/1989
Signer
Jeffrey R. Miller
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
104
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Table 80.308-A <br />Condition <br />Unprotected by sprinklers or <br />storage cabinets <br />Within storage cabinet in <br />unsprinklered building <br />In sprinklered building, <br />in storage cabinet <br />In sprink]ered building, <br />storage cabinet <br />*For pyrophoric liquids, <br />shall be used. <br />not <br />in <br />Exempt Amounts <br />Solids & Liquids Gases <br />(Pounds) (Cubic ft} <br />0 <br />4 <br />50 <br />8 100 <br />a conversion of 10 pounds per gallon <br />3. T e of Construction, In addition to the requirements <br />of the Structural Specialty Code for Group H, Division 2 and 3 <br />occupancies, buildings used for the storage of pyrophoric mat- <br />erials shall be of non-combustible construction. <br />4. Li,uid_-,Tight Floor. In addition to the provisions of <br />Section 80.301~z}, floors of storage areas shall be of liquid- <br />tight construction. <br />5. Containment. Secondary containment shall be provided <br />for storage rooms and buildings containing pyrophoric liquids <br />in accordance with the provisions of Section 80.3011}4. <br />6. Electrical Wirin and E ui ment. In addition to the <br />requirements of Section 80.301~r}, electrical wiring and <br />equipment in storage areas far pyrophoric gases and liquids <br />shall comply with the requirements for Class I, Division 2 <br />locations. <br />1. 5tara~e Conditions. <br />A~. Pal~~ eti ied storage of pyrophoric 1 i qui ds and <br />solids shall be limited to a maximum size of 10 feet by <br />10 feet by 5 feet high. Individual containers shall not <br />be stacked. <br />B. Aisles between storage piles shall be a minimum <br />of ten feet in width. <br />C. Tanks or containers larger than 500 gallons shall <br />not be permitted inside buildings. <br />8. Separation. In addition to the provisions of Section <br />80.301~n}, indoor storage of pyrophoric solids, liquids and <br />gases shall be isolated from incompatible hazardous materials <br />by one-hour fire-resistive noncombustible walls with openings <br />protected in accordance with UBC Section 3305~h}. <br />EXCEPTION: Storage in approved hazardous materials <br />storage cabinets built in accordance with the provisions <br />of Section 80.3010}. <br />fib} Exterior Sto. rage, <br />1. General. Exterior storage of pyrophoric solids, <br />1 i qu i ds and gases shat 1 be i n accordance with this subsection <br />and the general provisions specified i n Secti an 80.301, <br />~. Distance from Stora a to Ex osures, The separation <br />Ordinance - 49 <br />